Interface level transmitter is designed and certified in accordance with explosion-proof requirements. It is suitable for accurate measurement of process vessels and storage vessels in petroleum, chemical, electric power, steel, food, pharmaceutical and other industries.
![]()
Interface Level Transmitter can provide high-speed, reliable and high-precision continuous measurement in explosive gas environment. The output is in analog or digital form. The analog output form is two-wire 4-20mA+Hart; the digital output adopts RS485 (Modbus protocol) communication. When interface level transmitter working, it can be one or more floating balls. The floating ball can be suspended on the liquid-gas interface and liquid-liquid interface in the storage tank respectively, and move synchronously with them, WPX902 interface level transmitter realizes the real-time detection of the liquid level or interface of the liquid tanks.
Features Of WPX902 Interface Level Transmitter:
![]()


![]()
| Product Name | Interface Level Transmitter (WPX902) | |
| Output | 2-wire 4-20mA+Hart | Modbus |
| Output parameters | Liquid level, interface, temperature, liquid level difference | |
| Effective range | Hard rod: 100~6000mm; flexible rod: 1000~22000mm | |
| Number of measurement points | 1, 2 | 3 |
| Resolution | 16-bit D/A | Up to 0.1mm |
| Non-linear error | ≤ ±0.05% of full scale | |
| Repeatability | ≤ ±0.01% of full scale | |
| Value error | ≤ ±0.1% of full scale | |
| Temperature performance | ≤100ppm/℃ | |
| Response time | 100ms | |
| Working voltage | Rated working voltage: 24Vdc; normal working voltage: 10~30Vdc | |
| Operating current | <25mA (varies with range size) | <50mA (varies with range size) |
| Load characteristics | power supply 24V, current output
Maximum load 500Ω |
– |
| Protection class | IP67 | |
| Measurement blind zone | Upper blind zone can be none; lower blind zone minimum 20mm; blind zone of float height | |
| Temperature | Ambient temperature: -40℃~+70℃.
Medium temperature: -40℃~+70℃ (common type); -40℃~+200℃ (high temperature type) |
|
| Electronic bin material | Aluminum alloy, stainless steel 304 | |
| Medium density | ≥500kg/m³ | |
| Material of measuring rod | Stainless steel 304, 316, other materials can be customized | |
| Pressure-bearing characteristics | Rated 1.6mpa, can be customized | |
| Process interface | Thread or Flange | |
| Electrical interface | 2pcs M20*1.5 | |
| Operating environment | Outdoor, indoor | |
| Overpressure protection | 36V | |
| Polarity protection | Diode in series | |
| Electromagnetic compatibility | Comply with GB 21117-2007-T | |
| Insulation resistance | 20M(100V) | |
| Dielectric strength | 500V | |
| Other functions | 5-point temperature measurement; with field display and setting function | |
| Explosion-proof mark | Ex d ⅡB T6 Gb | |
![]()


![]()

![]()