Measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity, contact WEpower quickly!
Magflow Flow Meter is suitable for the fluid flow of various conductive fluids, such as water, acid and alkali solutions, salt solutions, water, sewage, corrosive liquids, and mud, mineral pulp, paper pulp, etc. But magflow flow meter cannot measure the flow of gas, steam and pure water.
Different Media, Different Lining Materials and different electrode Material
Lining Materials:Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Teflon(PFA)
Electrode Material:SUS316L, Hastelloy C, Ti, Ta, Pt
Converter | ||
Compact Type | IP65 | |
Remote Type | IP65(IP68 optional) | |
Measurement sensor of magflow flow meter/magnetic flow meter | ||
Nominal Diameter | DN15-DN1000 | |
Pressure rating (High pressure can be customized) |
DN6 – DN80, PN<4.0MPa | |
DN100 – DN150, PN<1.6MPa | ||
DN200 – DN1000, PN<1.0MPa | ||
DN1200 – DN2000, PN<0.6MPa | ||
Lining Material | Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Teflon(PFA) |
|
Electrode Material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt | |
Ingress Protection | IP68 | IP65 |
Medium Temperature | -25 – 180℃ | -10 – 80℃ |
Lining Temperature Range | Rubber liner:-20 …+60℃
High-temp rubber liner:-20…+90℃ PTFE liner: -20…+120℃ High-temp PTFE liner: -2O…+ 160℃ Polyurethane liner: -2O…+ 80℃ PFA: -20 …+180℃ |
|
Serial communications | RS-485 | |
Output | Current (4-20 mA) , pulse , frequency , state switch | |
Max measuring error | Measurement value ±0.5%(Flow speed > 1m/s); Measurement value ±0.5% ±2mm/s(Flow speed <1m/s) |
|
Repetitiveness | 0.15% | |
Power supply | 100-240VAC,50/60Hz, 22VDC-26VDC | |
Power consumption | Max 15VA | |
Signal cable | Apply only to remote type | |
Shielded cable | Signal section,wire: 0.5mm2 Cu /AWG20 |